Gwrthdroyddion Hybrid Solar + Storio Cyfres UPV-S
Manyleb AC 400V
| Model | UPV-S 0.4-50kW | UPV-S 0.4-100kW |
| Modd Annibynnol | ||
| Foltedd allbwn AC | 400V ± 10% (Rheoladwy) | |
| Cerrynt allbwn AC | 72A (Uchafswm o 79A) | 144A (Uchafswm o 159A) |
| Pŵer allbwn AC enwol | 50kW | 100kW |
| Pŵer Uchaf AC | 55kW | 110kW |
| Allbwn THDu | ≤3% (Llwyth llinol) | |
| Amledd AC | 50/60Hz | |
| AC PF | Rhestredig: 0.8~1 arweiniol neu ar ôl (yn dibynnu ar y llwyth) Gwirioneddol: 0.1~1 arweiniol neu ar ôl (yn dibynnu ar y llwyth) | |
| Gallu Gorlwytho | 120% 1 munud | |
| Ystod foltedd batri | 400~600V (Graddio 512V) | |
| Batri DC Uchafswm Cyfredol | 120A | 240A |
| Ystod Foltedd PV | 520~900V (MPPT 520V~800V) | |
| PV DC. Cerrynt Uchaf | 192A | 384A |
| Modd rhyngweithiol grid cyfleustodau | ||
| Ystod foltedd AC | 400V ± 15% | |
| Cerrynt graddio AC | 72A | 144A |
| Pŵer allbwn AC enwol | 50kW | 100kW |
| Amledd AC | 50Hz / 60Hz±2.5Hz | |
| Allbwn THDI | ≤3% | |
| AC PF | -1~1 | |
| Ystod foltedd batri | 400~600V (Graddio 512V) | |
| Cerrynt Uchaf DC y Batter | 120A | 240A |
| Ystod Foltedd PV | 520~900V (MPPT 520V~800V) | |
| PV DC. Cerrynt Uchaf | 192A | 384A |
| Arall | ||
| Effeithlonrwydd brig | ≥96% | |
| Amddiffyniad | OTP, AC OVP/UVP, OFP/UFP, EPO, Gwrthdroi Cyfnod AC, Methiant Ffan/Relay, OLP, GFDI, Gwrth-ibyrbryd | |
| Terfynau amddiffyn ffurfweddadwy | Terfyn Foltedd/Amledd AC Uchaf/Isaf, foltedd EOD y batri. | |
| Cysylltiad AC | 3P4W | |
| Arddangosfa | Sgrin gyffwrdd lliw 7" | |
| Cyfathrebu | RS485, CAN, Ethernet | |
| Ynysu | Trawsnewidydd Mewnol | |
| Corfforol | ||
| Oeri | Oeri aer gorfodol | |
| Sŵn | ≤70dB | |
| Amgaead | IP20/IP54 | |
| Uchder mwyaf | 3000m/10000 troedfedd (>2000m/6500 troedfedd yn lleihau'r gyfradd) | |
| Tymheredd gweithredu | -20℃~50℃(>45℃ diraddio) | |
| Lleithder | 0~95% (Dim cyddwyso) | |
| Maint (Ll*U*D) | 850 * 2400 * 1600mm | |
| Gosod | Sefyll ar y llawr | |
Manyleb AC 480V
| Model | UPV-S 0.5-50kW | UPV-S 0.5-100kW |
| Modd Annibynnol | ||
| Foltedd allbwn AC | 480V ± 10% (Rheoladwy) | |
| Cerrynt allbwn AC | 60A (Uchafswm o 66A) | 120A (Uchafswm o 132A) |
| Pŵer allbwn AC enwol | 50kW | 100kW |
| Pŵer Uchaf AC | 55kW | 110kW |
| Allbwn THDu | ≤3% (Llwyth llinol) | |
| Amledd AC | 60Hz | |
| AC PF | Rhestredig: 0.8~1 arweiniol neu ar ôl (yn dibynnu ar y llwyth) Gwirioneddol: 0.1~1 arweiniol neu ar ôl (yn dibynnu ar y llwyth) | |
| Gallu Gorlwytho | 120% 1 munud | |
| Ystod foltedd batri | 400~600V (Graddio 512V) | |
| Batri DC Uchafswm Cyfredol | 120A | 240A |
| Ystod Foltedd PV | 520~900V (MPPT 520V~800V) | |
| PV DC. Cerrynt Uchaf | 192A | 384A |
| Modd rhyngweithiol grid cyfleustodau | ||
| Ystod foltedd AC | 480V ± 15% | |
| Cerrynt graddio AC | 60A | 120A |
| Pŵer allbwn AC enwol | 50kW | 100kW |
| Amledd AC | 60Hz±0.2%±2.5Hz | |
| Allbwn THDI | ≤3% | |
| AC PF | -1~1 | |
| Ystod foltedd batri | 400~600V (Graddio 512V) | |
| Cerrynt Uchaf DC y Batter | 120A | 240A |
| Ystod Foltedd PV | 520~900V (MPPT 520V~800V) | |
| PV DC. Cerrynt Uchaf | 192A | 384A |
| Arall | ||
| Effeithlonrwydd brig | ≥96% | |
| Amddiffyniad | OTP, AC OVP/UVP, OFP/UFP, EPO, Gwrthdroi Cyfnod AC, Methiant Ffan/Relay, OLP, GFDI, Gwrth-ynysu | |
| Terfynau amddiffyn ffurfweddadwy | Terfyn Foltedd/Amledd AC Uchaf/Isaf, foltedd EOD y batri. | |
| Cysylltiad AC | 3P4W | |
| Arddangosfa | Sgrin gyffwrdd lliw 7" | |
| Cyfathrebu | RS485, CAN, Ethernet | |
| Ynysu | Trawsnewidydd Mewnol | |
| Corfforol | ||
| Oeri | Oeri aer gorfodol | |
| Sŵn | ≤70dB | |
| Amgaead | IP20/IP54 | |
| Uchder mwyaf | 3000m/10000 troedfedd (>2000m/6500 troedfedd yn lleihau'r gyfradd) | |
| Tymheredd gweithredu | -20℃~50℃(>45℃ diraddio) | |
| Lleithder | 0~95% (Dim cyddwyso) | |
| Maint (Ll*U*D) | 850 * 2400 * 1600mm | |
| Gosod | Sefyll ar y llawr | |
Ysgrifennwch eich neges yma a'i hanfon atom ni